CYB052 Dental Ultrasonic Scaler..
- Description
Specifications
|
Model
|
VR-K08AL
|
|
Control
|
Potentiometer
|
|
Handpiece
|
LED Detachable Pieze Handpiece HP-2 ×1
|
|
Operating Mode
|
Ultrasonic Scaling
|
|
External Water Hose
|
Available
|
|
Power Input
|
100-240VAC 50/60Hz
|
|
Foot Pedal
|
Wired Foot Pedal (IPX1) ×1
|
|
Main Unit Weight
|
0.75kg
|
|
Input Voltage
|
30VDC
|
|
Input Power
|
30VA~48VA
|
|
Vibration amplitude
|
Minimum: 1 um; deviation -50%
Maximum: 100 μ m; deviation +50% |
|
Output half-excursion force
|
Minimum: 0.1 N; deviation -50%.
Maximum: 2 N; deviation +50% |
|
Water pressure
|
0.01MPa~0.5MPa (0.1bar~5bar)
|
|
Frequency
|
25kHz~31KHz
|
|
Tips Hardness
|
50HRC
|
|
Packing Size
|
270*230*140mm
|
|
Storage Environment
|
Temperature:-20℃~55℃
Relative humidity:≤90% Atmospheric pressure:70kPa~106kPa |
|
Working Environment
|
Temperature:5℃~40℃
Relative humidity: ≤80% Atmospheric pressure: 70kPa~106kPa Applicative range of power supply and voltage: 100-240VAC 50/60Hz |
|
handpiece can be sterilized
|
134℃ and 0.22MPa pressure
|
|
Packing List
|
Main Unit * 1
HP-2 Handpiece * 1 Power Adapter * 1
Wired Foot Switch * 1
G1 Tips * 2
G2 Tip * 1
G4 Tip * 1 P1 Tip * 1
Puncture Device * 1
Pu Pipe * 1
Torque Torque Wrench * 1
O-ring * 2
Instruction Manual * 1
Tips instruction Manual * 1
Tips Reprocessing instruction * 1
QC Certificate * 1
|
Features
1. Full-automatic frequency tracking system: Automatically detects the optimal working state for more stable performance.
2. Detachable Handpiece: Can be sterilized at high temperature (134°C) and high pressure (0.22MPa).
3. Mechanically adjustable output power and water flow: 10 adjustable power levels and wide-range water flow control to meet diverse user needs. 4. Applications: Scaling and periodontal treatment
Product Description








Company Profile



Contact Us
Email :admin@denspay com
Tel :+86-0371-63685210
Fax :+86-0371-63685210
Email :admin@denspay com
Tel :+86-0371-63685210
Fax :+86-0371-63685210
Maintenance Guide
1. Daily maintenance
1.1 Please disinfect the handpiece, scaler tip, torque wrench, U file holder wrench and other accessories before each use to prevent cross infection. It is recommended to use sterilisation bags for sterilisation.
1.2 After the treatment, unscrew the scaler tip with a wrench, wipe the handpiece and the scaler tip surface with an alcohol
cotton ball to remove blood stains.
1.3 After the treatment, turn off the power, ensure that the main unit is in a power-off state, wipe the surface of the equipment with clean water.
1.4 It is recommended to use pure water or distilled water, in order to reduce the blocking of the pipeline by scale.
2. Regular maintenance
2.1 Regularly clean the water inlet, use water to flush the pipeline. Disassemble and clean the solenoid valve if possible to
ensure that the pipeline is clear.
1.1 Please disinfect the handpiece, scaler tip, torque wrench, U file holder wrench and other accessories before each use to prevent cross infection. It is recommended to use sterilisation bags for sterilisation.
1.2 After the treatment, unscrew the scaler tip with a wrench, wipe the handpiece and the scaler tip surface with an alcohol
cotton ball to remove blood stains.
1.3 After the treatment, turn off the power, ensure that the main unit is in a power-off state, wipe the surface of the equipment with clean water.
1.4 It is recommended to use pure water or distilled water, in order to reduce the blocking of the pipeline by scale.
2. Regular maintenance
2.1 Regularly clean the water inlet, use water to flush the pipeline. Disassemble and clean the solenoid valve if possible to
ensure that the pipeline is clear.
3. Disinfection Instructions
3.1 Removable handpiece, scaler tip and wrench are sterilized at 134℃ high temperature and high pressure. Before sterilization,
please use compressed air to blow away the liquid remaining in the handpiece.
3.2 When sterilizing, be sure to remove the scaler tip from the handpiece and avoid mixing it with other instruments for
sterilization.
In the process of sterilising the scaler tip and handpiece together, please pay attention to any external damage to the handpiece. It is strictly forbidden to apply any protective oil on the handpiece surface.
3.3 When using alcohol for disinfection, soak a piece of clean dry gauze in 75% ethanol disinfectant, then use the gauze to wipe the surface of the part to be disinfected twice for 3 minutes. Air dry naturally or wipe any residual disinfectant off with a clean, dry cloth.
4. Precautions for use
4.1 When a non-pressurised water source is used, the water surface of the non-pressurised water source should be more than one metre above the patient's head.
4.2 The handpiece and the tail wire socket must be kept dry when connected.
4.3 Please do not pull out the handpiece when the foot pedal is pressed and the product vibrates.
4.4 Do not use disposable scaler tips or scaler tips that do not correspond to the standard threads. Incorrect threads, roughness and rusting of the scaler tip can damage the threads of the handpiece and cause irreparable damage to the ultrasonic scaler.
4.5 It is strictly forbidden to disinfect the handpiece in the following ways: boiling the handpiece in a solution; soaking the
handpiece in disinfectant such as iodine, alcohol, glutaraldehyde, etc.; baking it in an oven or microwave at high temperature.
4.6 Please do not pull the tail wire during the use of the product, in order to avoid detaching the handpiece from the tail wire socket.
5. Protection and Storage
5.1 This product should be stored with care and away from vibration sources, and should be installed or stored in a cool, dry and ventilated place.
5.2 Do not store with toxic, corrosive, flammable or explosive items.
5.3 When this product is not used for a long time, it should be powered on and off once a month for 5 minutes each time.
5.4 This product should be stored in an environment with a temperature of -20 ℃~55 ℃, a relative humidity less than 90%.
5.5 When this equipment is not in use, the power switch should be turned off and the power plug should be unplugged.
3.1 Removable handpiece, scaler tip and wrench are sterilized at 134℃ high temperature and high pressure. Before sterilization,
please use compressed air to blow away the liquid remaining in the handpiece.
3.2 When sterilizing, be sure to remove the scaler tip from the handpiece and avoid mixing it with other instruments for
sterilization.
In the process of sterilising the scaler tip and handpiece together, please pay attention to any external damage to the handpiece. It is strictly forbidden to apply any protective oil on the handpiece surface.
3.3 When using alcohol for disinfection, soak a piece of clean dry gauze in 75% ethanol disinfectant, then use the gauze to wipe the surface of the part to be disinfected twice for 3 minutes. Air dry naturally or wipe any residual disinfectant off with a clean, dry cloth.
4. Precautions for use
4.1 When a non-pressurised water source is used, the water surface of the non-pressurised water source should be more than one metre above the patient's head.
4.2 The handpiece and the tail wire socket must be kept dry when connected.
4.3 Please do not pull out the handpiece when the foot pedal is pressed and the product vibrates.
4.4 Do not use disposable scaler tips or scaler tips that do not correspond to the standard threads. Incorrect threads, roughness and rusting of the scaler tip can damage the threads of the handpiece and cause irreparable damage to the ultrasonic scaler.
4.5 It is strictly forbidden to disinfect the handpiece in the following ways: boiling the handpiece in a solution; soaking the
handpiece in disinfectant such as iodine, alcohol, glutaraldehyde, etc.; baking it in an oven or microwave at high temperature.
4.6 Please do not pull the tail wire during the use of the product, in order to avoid detaching the handpiece from the tail wire socket.
5. Protection and Storage
5.1 This product should be stored with care and away from vibration sources, and should be installed or stored in a cool, dry and ventilated place.
5.2 Do not store with toxic, corrosive, flammable or explosive items.
5.3 When this product is not used for a long time, it should be powered on and off once a month for 5 minutes each time.
5.4 This product should be stored in an environment with a temperature of -20 ℃~55 ℃, a relative humidity less than 90%.
5.5 When this equipment is not in use, the power switch should be turned off and the power plug should be unplugged.
FAQ
Q1. How do I order from you?
A1. We will make quotation after you send us your purchase plan (including product name, model and quantity). If you agree with the quotation, please send us your company name, address and telephone for goods delivery. We will make proforma invoice and inform you the payment way. Goods delivery details will also be informed accordingly.
Q2. How long is your delivery time?
A2. Generally it is 7-15 days if the goods are in stock. or it is 15-30 days if the goods are not in stock, it is according to
quantity.
Q3. Can you bear the freight?
A3. The price we quote you is our factory price, not included other cost, like shipping cost and importation costs, so this cost you need to shoulder. Our distributors also need to shoulder this cost, as we usually give them the factory price and they use their own freight forwarder to transport the goods.
Q4. What is your terms of payment?
A4. Full payment should be made within 5 working days of placing your order. If you have another question pls feel free to contact us.
A1. We will make quotation after you send us your purchase plan (including product name, model and quantity). If you agree with the quotation, please send us your company name, address and telephone for goods delivery. We will make proforma invoice and inform you the payment way. Goods delivery details will also be informed accordingly.
Q2. How long is your delivery time?
A2. Generally it is 7-15 days if the goods are in stock. or it is 15-30 days if the goods are not in stock, it is according to
quantity.
Q3. Can you bear the freight?
A3. The price we quote you is our factory price, not included other cost, like shipping cost and importation costs, so this cost you need to shoulder. Our distributors also need to shoulder this cost, as we usually give them the factory price and they use their own freight forwarder to transport the goods.
Q4. What is your terms of payment?
A4. Full payment should be made within 5 working days of placing your order. If you have another question pls feel free to contact us.
You may also like
Money Return
DDP Available
Welcome to store
Welcome to store
24/7 Online Support